Search results for "Bonner sphere"
showing 9 items of 9 documents
Characterization of a Be(p,xn) Neutron Source for Fission Yields Measurements
2013
We report on measurements performed at The Svedberg Laboratory (TSL) to characterize a proton-neutron converter for independent fission yield studies at the IGISOL-JYFLTRAP facility (Jyv\"askyl\"a, Finland). A 30 MeV proton beam impinged on a 5 mm water-cooled Beryllium target. Two independent experimental techniques have been used to measure the neutron spectrum: a Time of Flight (TOF) system used to estimate the high-energy contribution, and a Bonner Sphere Spectrometer able to provide precise results from thermal energies up to 20 MeV. An overlap between the energy regions covered by the two systems will permit a cross-check of the results from the different techniques. In this paper, th…
GEANT4 simulation of the neutron background of the C6D6 set-up for capture studies at n_TOF
2014
The neutron sensitivity of the C6D6 detector setup used at n_TOF facility for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has beeni mplemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with anatC sample, showing an excellent agreement above 1 keV. At lower energies, an additional compo…
A neutron spectrometer for studying giant resonances with (p, n) reactions in inverse kinematics
2014
A neutron spectrometer, the European Low-Energy Neutron Spectrometer (ELENS), has been constructed to study exotic nuclei in inverse-kinematics experiments. The spectrometer, which consists of plastic scintillator bars, can be operated in the neutron energy range of 100 keV to 10 MeV. The neutron energy is determined using the time-of-flight technique, while the position of the neutron detection is deduced from the time-difference information from photomultipliers attached to both ends of each bar. A novel wrapping method has been developed for the plastic scintillators. The array has a larger than 25% detection efficiency for neutrons of approximately 500 keV in kinetic energy and an angul…
Characterization of a neutron-beta counting system with beta-delayed neutron emitters
2016
Abstract A new detection system for the measurement of beta-delayed neutron emission probabilities has been characterized using fission products with well known β-delayed neutron emission properties. The setup consists of BELEN-20, a 4π neutron counter with twenty 3He proportional tubes arranged inside a large polyethylene neutron moderator, a thin Si detector for β counting and a self-triggering digital data acquisition system. The use of delayed-neutron precursors with different neutron emission windows allowed the study of the effect of energy dependency on neutron, β and β–neutron rates. The observed effect is well reproduced by Monte Carlo simulations. The impact of this dependency on …
Neutron fluence spectrometry using disk activation
2009
Abstract A simple and robust detector for spectrometry of environmental neutrons has been developed. The technique is based on neutron activation of a series of different metal disks followed by low-level gamma-ray spectrometry of the activated disks and subsequent neutron spectrum unfolding. The technique is similar to foil activation but here the applied neutron fluence rates are much lower than usually in the case of foil activation. The detector has been tested in quasi mono-energetic neutron fields with fluence rates in the order of 1000–10000 cm −2 s −1 , where the obtained spectra showed good agreement with spectra measured using a Bonner sphere spectrometer. The detector has also b…
The alanine detector in BNCT dosimetry: Dose response in thermal and epithermal neutron fields
2014
Purpose: The response of alanine solid state dosimeters to ionizing radiation strongly depends on particle type and energy. Due to nuclear interactions, neutron fields usually also consist of secondary particles such as photons and protons of diverse energies. Various experiments have been carried out in three different neutron beams to explore the alanine dose response behavior and to validate model predictions. Additionally, application in medical neutron fields for boron neutron capture therapy is discussed. Methods: Alanine detectors have been irradiated in the thermal neutron field of the research reactor TRIGA Mainz, Germany, in five experimental conditions, generating different secon…
A neutron source for IGISOL-JYFLTRAP : Design and characterisation
2017
A white neutron source based on the Be(p, nx) reaction for fission studies at the IGISOL-JYFLTRAP facility has been designed and tested. 30MeV protons impinge on a 5mm thick water-cooled beryllium disc. The source was designed to produce at least 1012 fast neutrons/s on a secondary fission target, in order to reach competitive production rates of fission products far from the valley of stability. The Monte Carlo codes MCNPX and FLUKA were used in the design phase to simulate the neutron energy spectra. Two experiments to characterise the neutron field were performed: the first was carried out at The Svedberg Laboratory in Uppsala (SE), using an Extended-Range Bonner Sphere Spectrometer and …
Measurements of the 90,91,92,94,96 Zr n, gamma cross-sections at n_TOF
2005
Neutron capture cross sections of the 90,91,92,94,96Zr have been measured over the energy range from 1 eV to 1 MeV at the spallation neutron facility n TOF at CERN in 2003. The innovative features of the neutron beam, in particular the high instantaneous flux, the high energy resolution and low background, together with improvements of the neutron sensitivity of the capture detectors make this facility unique for neutron-induced reaction cross section measurements with much improved accuracy. The preliminary results of the Zr measurements show capture resonance strengths generally smaller than in previous measurements. Peer Reviewed
Position-sensitive neutron detector
2002
Abstract A position-sensitive neutron detector has been developed for use in nuclear physics research. The detector consists of a ∅5.5 cm×100 cm long quartz tube filled with liquid scintillator viewed from both ends by photomultipliers and enclosed in a light-tight titanium container. The properties of the detector were determined both experimentally and by Monte Carlo simulations (EFEN code). A time resolution of 0.4 ns was reached resulting in the position resolution of less than 4 cm. The neutron registration efficiency varies from 36% to 20% within neutron energy range 1–10 MeV and is practically independent of the position along the detector length. Good n–γ separation is achieved for …